Range | DIESEL |
Frequency (Hz) | 50 Hz |
Max power (kW) | 3.40 |
Nominal voltage (V) | 230 |
Number of Phase | Single phase |
Fuel | Diesel Fuel |
Tank (L) | 16 |
75% cons. (l/h) | 0.90 |
75% Autonomy (h) | 17.80 |
Sound power level guaranteed LwA dB(A) | 108 |
Acoustic pressure level @1m in dB(A) | 92 |
Acoustic pressure level @7m in dB(A) | 78 |
Engine brand | KOHLER |
Engine ref. | KD350E |
Engine Type | Diesel O.H.V. |
Start | Electrical |
Oil shutdown | Oui |
Displacement (cm3) | 349 |
Oil system capacity including filters (l) | 1.20 |
Technology | Brushless |
AVR Regulation | No |
Indication of protection | IP 23 |
Insulation class | H |
Plug type 50 Hz | 2 230V 10/16A sockets - circuit breaker |
Length (cm) | 81 |
Width (cm) | 55.50 |
Height (cm) | 59 |
Dry Weight (kg) | 84 |
Packaging type | Box |
Length (cm) | 82 |
Width (cm) | 56.50 |
Height (cm) | 60 |
Weight (kg) | 87 |
Pallet type | 120/80 |
Number of box by pallet | 6 |
Pallet height (cm) | 193 |
weight of the packaged Pallet (kg) | 532 |
Generating set guaranteed 3 years | |
KOHLER air-cooled industrial engine | |
Large Autonomy | |
Comfort of prehension thanks to the ergonomic handles | |
Electric starter with batteries without maintenance |
User and maintenance manual | |
Floor maintaining slot | |
Ergonomic handle grip |
Réf. 2 | Description | |
---|---|---|
![]() |
This set includes the hour meter and the differential circuit breaker | This set includes the hour meter and the differential circuit breaker. |
![]() |
The manual changeover switch is used to connect and disconnect a generating set manually to a domestic circuit when there is a power cut | The manual changeover switch is used to connect and disconnect a generating set manually to a domestic circuit when there is a power cut. |
![]() |
RKDS1 - Maintenance kit for KOHLER CH350E and CH440E engines (Diesel 6000 E XL C - Diesel 6500 TE XL C) | Maintenance kit for KOHLER CH350E and CH440E engines (Diesel 6000 E XL C - Diesel 6500 TE XL C). |
![]() |
Cover for SDMO 's generating sets, welding sets and water pumps | Cover for SDMO 's generating sets, welding sets and water pumps |
![]() |
Male plugs for all models made up of : 2 x 16 A/230 V, EEC17: 1 x 16A/230 V, 1 x 32A/230 V and 1 x 16A/400V | Male plugs for all models made up of : 2 x 16 A/230 V, EEC17: 1 x 16A/230 V, 1 x 32A/230 V and 1 x 16A/400V |
![]() |
For earthing your generator set. Galvanised 1 m long spike, supplied with 2 m of 10 mm² cable | For earthing your generator set. Galvanised 1 m long spike, supplied with 2 m of 10 mm² cable. |
![]() |
Removable storage box | Removable storage box |
![]() |
kit of two diferential removable adapters for domestic sockets. Schema for ground bonding with isolated neutral | kit of two diferential removable adapters for domestic sockets. Schema for ground bonding with isolated neutral |