GENERAL SPECIFICATIONS

Range DIESEL
Frequency (Hz) 50 Hz
Max power (kW) 3.40
Nominal voltage (V) 230
Number of Phase Single phase
Fuel Diesel Fuel
Tank (L) 16
75% cons. (l/h) 0.90
75% Autonomy (h) 17.80
Sound power level guaranteed LwA dB(A) 108
Acoustic pressure level @1m in dB(A) 92
Acoustic pressure level @7m in dB(A) 78

ENGINE SPECIFICATIONS

Engine brand KOHLER DIESEL
Engine ref. KD350E_C5
Distribution Diesel O.H.V.
Start Electrical
Oil shutdown Oui
Displacement (cm3) 349
Oil system capacity including filters (L) 1.20

ALTERNATOR SPECIFICATIONS

Technology Brushless
AVR Regulation No
Indication of protection IP 23
Insulation class H

PLUGS AND PANEL DESCRIPTIVE

Plug type 50 Hz 2 230V 10/16A sockets - circuit breaker

DIMENSIONS AND WEIGHT

Length (cm) 81
Width (cm) 55.50
Height (cm) 59
Dry Weight (kg) 84

PACKAGING

Packaging type Box
Length (cm) 82
Width (cm) 56.50
Height (cm) 60
Weight (kg) 87
Pallet type 120/80
Number of box by pallet 6
Pallet height (cm) 193
weight of the packaged Pallet (kg) 532

PRODUCT ADVANTAGES

Entire group guaranteed 3 years
KOHLER air-cooled industrial engine
Large Autonomy
Comfort of prehension thanks to the ergonomic handles
Electric starter with batteries without maintenance

ACCESSORIES SUPPLIED

User and maintenance manual
Floor maintaining slot
Ergonomic handle grip

OPTIONS

Réf. 2 Description
R01 This set includes the hour meter and the differential circuit breaker.
R05M The manual changeover switch is used to connect and disconnect a generating set manually to a domestic circuit when there is a power cut.
RKB1HD Trolley kit for the generating sets of 6kW or below
RKDS1 Maintenance kit for KOHLER CH350E and CH440E engines (Diesel 6000 E XL C - Diesel 6500 TE XL C).
RH1 Cover for SDMO 's generating sets, welding sets and water pumps
RPM Male plugs for all models made up of : 2 x 16 A/230 V, EEC17: 1 x 16A/230 V, 1 x 32A/230 V and 1 x 16A/400V
RPQ For earthing your generator set. Galvanised 1 m long spike, supplied with 2 m of 10 mm² cable.
RBAC Removable storage box